-20%
, , , ,

PrimoChill True™ Infused – Insanely Concentrated Liquid Pre-Mix (8oz) – Opaque Candy Purple SX

Availability:

Out of stock


Primary pictures shows fluid mixed and in a reservoir (not included) to illustrate the final color.
This is an opaque fluid that is a solid color and will NOT allow light to pass through.

One 8oz Bottle Makes One Gallon of Coolant!

Warning: This product is intended for Experienced/Professional Users Only. Please read full disclaimer at the bottom of page prior to purchasing!

$19.99 $24.95

Out of stock

PrimoChill Opaque TRUE™

Opaque True is a long-awaited astounding breakthrough in showcase coolant. The solid vibrant color will set the edge on your next build and provide stunning pictures of sheer beauty to be appreciated by all. Opaque is classified as a showcase style coolant but performance is comparable to any of its transparent counterparts.

FEATURES

True_RepeatedChemistry67x67

Repeatable Chemistry

Repeatable chemistry for True™ colors every time.
True_Waterborne67x67

Waterbased Concentrate

Waterbased pre-mix concentrate solution.
True_PreMeasured67x67

Pre-Measured & Pre-Dyed

Pre-measured and pre-dyed.  Ready to mix with water and add to your system.
True_Clean67x67

Clean

Cleanest coolant formulation in the water cooling industry.
True_Safe67x67

Safe on Most Materials

Safe on all plastics, rubbers, miscellaneous gasket materials, and acrylic.
True_EcoFriendly67x67

Preservative & APE Free

Preservative and APE free.
True_Preventive67x67

Special Inhibitors

Special inhibiting ingredients that prevent sludge build up of algae and galvanic corrosion.
True_TwoYear67x67

Shelf Life

2 year shelf life (unopened in original Bottle)

SPECS

Bottle Size: 8 fluid ounces

Shelf Life: 2 years (unopened)

Mix Ratio: Add to 1 gallon Distilled Water

Added Value: Opaque Sys Prep Included

Compatible Additives / Fluids:TRUE only

Warnings/Cautions:
Parts Included
Opaque Sys Prep Instructions
Opaque True™ Instructions
Warnings/Cautions:

PRODUCT USAGE DISCLAIMER
USE AT YOUR OWN RISK.
PRIMOCHILL IS NOT RESPONSIBLE FOR DAMAGED COMPONENTS.This product is intended for Experienced/Professional Users Only.
Opaque coolants are to be monitored daily to ensure that there is no color change or any collection or separation of True Opaque.

Please be aware of the following before using any colored fluid in your system.

Preparation
All water-cooling loops (existing as well as new) must be prepared using the included Opaque Sys Prep

Maintenance
As with all custom loop water-cooling, continual maintenance and daily inspection is required. If you intend to “fill your loop and forget it”, we STRONGLY recommend NOT using True Opaque. True Opaque will need to be replaced every 6 months or sooner, depending on the complexity and conditions of your loop. This will be required to maintain the aesthetic appeal of your loop.

Warnings/Cautions

Compatibility
Use of this product with aluminum components (such as aluminum constructed radiators) is STRONGLY DISCOURAGED and will void the fluid warranty. PrimoChill will not support or replace fluids used with an aluminum radiator.
Do not mix ANY additional additives, coolants or silver coils with Opaque True. This will change the formulation of Opaque True which can cause the fluid to solidify or break apart.

Staining
The use of any colored fluids/dyes WILL ABSOLUTELY stain your components in your cooling loop including rigid and flexible tubing, acrylic reservoirs, and blocks. Prolonged use will cause permanent staining of your components. Severity of staining will be based on the color. Use of this product is at your own risk. PrimoChill will not replace stained components.

Color Loss
During the initial application of True Opaque, the product may change/lose its original color when added to your loop within the first 24-48 hours. This is a common, well known occurrence. If this happens to your system, immediately drain and flush it out with DI or Distilled water. Once the system has been drained and cleaned, refill your system with True Opaque fluid once again. True Opaque will over time help neutralize your cooling loop, which will then stabilize the color.

Collection or separation of particles
As with all Opaque fluids, buildup of particles in the micro channels of water blocks will occur over time. This buildup/blockage can cause the fluid in your system to flow slower and could possibly stop flow all together. System pressure also plays a role in how well True Opaque performs. The combination of high pressure loops and microchannel water blocks will accelerate the breakdown of True Opaque coolant. We STRONGLY recommend using a pressure relief valve in every water-cooling loop. If you notice ANY collection or separation of True Opaque, drain and rinse your system IMMEDIATELY. Running your system with True Opaque coolant after it has separated can cause unknown issues and could require the user to remove, open, and clean each individual component in the system.
Parts Included
PrimoChill Opaque True™ – 8oz

Opaque Sys Prep – 15mL
Opaque Sys Prep Instructions
1. Install your cooling loop and double-check connections to ensure loop is “closed”. No Leaks!
2. Empty bottle of SysPrep into 1 US Gallon of fresh DI or Distilled water, and shake for 30 seconds.
3. Add mix to cooling loop.
4. Fill loop with treated water and be sure to remove as many air bubbles as possible.
5. Start loop pump and begin circulating the treated water.
6. Run treated water for at least 72 hours to ensure loop is properly flushed and treated.
7. Drain System. Inspect drained water for debris or foreign particles. Dispose of drained water. Repeat flush if needed.
8. Fill loop with your choice of Opaque TRUE and begin water-cooling.**

Notes: During the “flush” the water may become cloudy and foaming may occur. Do not worry! This means the SysPrep is doing its job! If after “flushing” the loop debris is still present, please repeat “flush” again.

** Residual treated water left in your loop is not harmful. If you prefer to remove it, do a simple rinse of the loop with fresh DI or Distilled Water. This rinse will not affect the results of the Sys Prep just performed.
Opaque True™ Instructions
Opaque True:
1. Finish Opaque Sys Prep Instructions. (Required for new builds as well as existing system refills).
2. Mix 8oz Opaque True™ bottle with 1 gallon distilled water.
3. Shake casually to incorporate the pre-mix with the water. (Excessive force or mixing not required)
4. Fill your system with fluid using your preferred priming method.